Cameca SX Five FE EPMA - Status: In Use

  • Current Status: In Use
  • Training: View Topics/Sessions
  • Use Rates:
    • External Academic & Government: $78.00/Hour
    • External Affiliated Commercial/Industrial: $157.50/Hour
    • External Commercial/Industrial: $210.00/Hour
    • External International Academic: $104.00/Hour
    • Internal Standard: $52.00/Hour
  • Service: Request Service Quote. The Staff rate is $50/hour (Internal) and $55 /hour (External) in addition to the instrument rate.
  • Building: NANO (0070)
  • Room: EPMA Lab (285)
  • In Cleanroom: No
  • Main Contact: Andres Trucco
Rate Notes: Published rates are for first 8 hours. Rate then decreases to $13/hr. for Internal Standard - $19.50/hr. for External Academic & Gov. - $26/hr. External Int. Academic - $39/hr. for External Affiliated Commercial/Industrial - $52/hr. for External Commercial/Industrial.
    Runs not to exceed 24 hours in total.

    Field Emission Electron Probe Micro Analyzer for Quantitative Analysis and X-Ray Mapping with Sub-Micron Spatial Resolution. The SXFiveFE provides:
    - Field emission source and SEM with 6nm resolution @ 25-30keV.
    - Automation capabilities for-long term unattended analysis.
    - Quantitative analysis at submicron scale.
    - High quality minor and trace element analysis.
    - Mapping at high spartial resolution.
    - High precision WDS spectrometers for high reproducibility.
    - Detection limits down to 100ppm (0.01%)

    Introduction to Electron Probe Micro analysis
    Electron Probe Micro Analysis Wiki
    CAMECA SXFive FE

    Latest Status Log EntryMar 6, 2024 - Resource Status Up - Ready to use. 5V power supply replaced.

SXFiveFE Main Specifications and Configuration:

- Maximum accelerating voltage: 30kV.

- Beam diameter in analytical mode:
- 80nm @ 20kV, 10nA.
- 100nm @ 10kV, 10nA.
- 150nm @ 5KV, 10nA.

- Maximum beam current: 400nA to 600nA

- Beam Stability: +- 0.5% per hour @ 20kV, 20nA.

- Installed detectors: 4 BSE’s, SE and EDS (EDAX Element).

- Installed WDS Spectrometers and configurations:
* SP1: Inclined, less sensitive to specimen height, for mapping rough surface samples. Low pressure with LiF, PET, TAP and PC2 crystals installed.
* SP2: Vertical, high pressure for greater sensitivity, with LLiF and LPET crystals.
* SP3: Vertical, low pressure, with TAP and PC0 crystals.
* SP4: Vertical, low pressure, with LPET and TAP crystals.

-Crystals Elemental Coverage

- Available standards:
-Geology Standards
-Metallurgy Standards
-44 Metal STD
-Rare Earth

- Stage: The SXFiveFE is equipped with a high precision stage capable of 0.1um micro steps reproducible within 1um by using optical encoders.

- Available holders and sample size specifications:
* HO6, HOTS2+2, HOTS4

- Sample Preparation

An active Gatorlink login is required to create a new reservation.